CT17 Spring Operating Mechanism

1.The mechanism structure is designed as a sandwich structure, which is easy to install and has a simple structure; There are two types of energy storage methods for mechanism closing: electric and manual; There are two types of opening and closing operations: electromagnets and manual buttons; It can be manually opened and closed slowly, and has a mechanical interlocking function where the closing position cannot be operated.

2.The mechanism can be installed vertically or upside down, and the connection and cooperation are very convenient.

3.The mechanism has high energy storage efficiency, low noise, smooth movement, compact structure, large closing power, small size, and light weight


  Contact Now
Product Details

Product Description

The CT17 spring operating mechanism adopts a clamp type structure, with the energy storage motor and driving part, closing cam and connecting rod, auxiliary switch, etc. arranged in the middle of the left and right side plates, ensuring reasonable force and good stability of each part. The closing spring, wiring terminal, and travel switch are arranged on the outer side of the side panel for easy maintenance and replacement. The main shaft has rolling bearings at both ends, which are flexible in rotation and have high transmission efficiency. The mechanism is installed on the frame of the fixed cabinet and circuit breaker using M12 screws through the installation holes on two angle steels fixed on the left and right side panels. The output shaft of the mechanism is located at the rear of the mechanism, and the end face of the mounting seat is arranged in parallel. The mechanism can be installed vertically, upside down, or in any direction, suitable for various circuit breaker mechanisms.

Product Technical Parameters

1.Mechanism output angle: 51-54 °

2.Closing power 350J-500J

3.Rated voltage of motor DC/AC220V, DC110V

4.Motor energy storage time ≤ 15s

Application Scenarios

The upper limit of the ambient air temperature is+40 ℃, and the lower limit is -30 ℃. The altitude does not exceed 3000M, and the relative humidity is not more than 90% on a monthly basis. The air pollution level does not exceed Level III in GH5582, and the wind pressure does not exceed 700Pa (equivalent to a wind speed of 34m/s). It is installed outdoors or indoors, and can be customized according to actual requirements