Main application and performanceCJ8 series three-position electric actuator adopts modularized structure, which has the advantages of simple structure, reliable action, smooth operation, reliable self-locking, accurate repetitive positioning, small volume, light weight, easy installation and commissioning.
Contact Now
Worm gear transmission, at the same time with manual, electricWith slow split and slow close function.
Contact Now
Worm gear transmission, at the same time with manual, electricWith slow split and slow close function.
Contact Now
Product descriptionThe CJ34 operating mechanism can be used to close and open ZF10-126, ZF5T-126, ZF12-126, ZF4A-126, ZF31-126, ZF21-126, ZF29-126, ZF25-126, ZF39-126, ZF35-126, ZF34-252, as well as disconnecting, earthing and load switches. The required torque is comparable to that of the above mentioned switches.The closing and opening positions and output angles of the mechanism are ensured by a clutch and worm gearing through the forward and reverse function of the motor. The mechanism has both manual and electric functions.Operating conditions1.
Contact Now
Product DescriptionZW20 series outdoor vacuum circuit breaker adopts vacuum extinguisher and SF6 gas as insulation medium, it is the improved product of ZW20 column vacuum circuit breaker. The case adopts the gas sealing, explosion-proof and insulating structure technology of VSP5 introduced from abroad, and the inlet and outlet conduits are also improved in sealing performance, with excellent overall sealing performance.
Contact Now
Output torque 100-252N-m (both available)Output angle 60-300°(both available)Voltage range DC110V, DC125, DC220V  
Contact Now
Product DescriptionThe CYD-4 series hydraulic disc spring operating mechanism uses disc springs as energy storage components. The disc springs have excellent force characteristics, are not affected by environmental temperature, store a large amount of energy, and have smooth force characteristics. Its structure adopts an integrated module design without pipeline connection.
Contact Now
Product DescriptionThe CYD-4 series hydraulic disc spring operating mechanism uses disc springs as energy storage components. The disc springs have excellent force characteristics, are not affected by environmental temperature, store a large amount of energy, and have smooth force characteristics. Its structure adopts an integrated module design without pipeline connection.
Contact Now
Byword1. Can realize manual and electric energy storage.2. Can realize manual and electric breaking and closing.3. Can realize slow breaking and closing function.4. Can allow automatic reclosing.5.
Contact Now
Byword1. Can realize manual and electric energy storage.2. Can realize manual and electric breaking and closing.3. Can realize slow breaking and closing function.4. Can allow automatic reclosing.5.
Contact Now
Byword1. can realize electric energy storage. 2. can realize electric opening and closing. 3. can allow automatic reclosing. 4.
Contact Now
Product DescriptionIt has a rotating arc extinguishing method that utilizes the electromagnetic force generated by the current flowing in the main circuit of the switch to cut off the current, reducing the burden on the operating mechanism.The shell is formed by hydraulic expansion with 1500 air pressures, with the smallest welding length and the strongest circular shape to withstand internal and external pressure, thus maintaining high accuracy and high quality.Product Technical Parameters1.Rated voltage: 12KV2.Rated current: 630A3.Rated short time withstand current: 20KA4.Rated short time wi
Contact Now
Product abstractThe CT32 operating mechanism can be used to close and open ZF10-126, ZF5T-126, ZF12-126, ZF4A-126, ZF31-126, ZF21-126, ZF29-126, ZF25-126, ZF39-126, ZF35-126, ZF34-252, as well as disconnecting, earthing and load switches. The required torque is comparable to that of the above mentioned switches.The closing and opening positions and output angles of the mechanism are ensured by a clutch and worm gearing through the forward and reverse function of the motor. The mechanism has both manual and electric functions.Operating conditions1.
Contact Now
Product DescriptionThe main hydraulic components of CYD-8 series hydraulic disc spring actuator include combined disc spring, working cylinder, control valve, oil pump motor, energy storage cylinder, travel switch, safety valve, high-pressure oil drain valve, low-pressure oil tank, connecting seat and other components; adopting the disc spring as the energy storage component, the disc spring has excellent force characteristics, is not affected by the ambient temperature, the stored energy is large, and the force characteristics are smooth.
Contact Now
Product DescriptionThe main hydraulic components of CYD-8 series hydraulic disc spring actuator include combined disc spring, working cylinder, control valve, oil pump motor, energy storage cylinder, travel switch, safety valve, high-pressure oil drain valve, low-pressure oil tank, connecting seat and other components; adopting the disc spring as the energy storage component, the disc spring has excellent force characteristics, is not affected by the ambient temperature, the stored energy is large, and the force characteristics are smooth.
Contact Now
Product descriptionThe CJ8-6 operating mechanism can be used to close and open ZF23-126, ZF□-126, as well as disconnectors, earth switches and load switches, with torque requirements comparable to those of the above mentioned switches.The mechanism has three stations. One mechanism can operate one disconnecting switch and one earthing switch for closing and breaking of the disconnecting switch as well as closing and breaking of the earthing switch. The mechanism has both manual and electric operation modes.Operating conditions1. Ambient air temperature: upper limit +60℃, lower limit -30.2.
Contact Now
Product abstractThe CT32 operating mechanism can be used to close and open ZF10-126, ZF5T-126, ZF12-126, ZF4A-126, ZF31-126, ZF21-126, ZF29-126, ZF25-126, ZF39-126, ZF35-126, ZF34-252, as well as disconnecting, earthing and load switches. The required torque is comparable to that of the above mentioned switches.The closing and opening positions and output angles of the mechanism are ensured by a clutch and worm gearing through the forward and reverse function of the motor. The mechanism has both manual and electric functions.Operating conditions1.
Contact Now
BywordCan realize manual and electric energy storage.Can realize manual and electric breaking and closing.Can realize slow breaking and closing function.Can allow automatic reclosing 5.
Contact Now
Byword1. can realize manual and electric energy storage.2. can realize manual and electric breaking and closing.3. can realize slow breaking and closing function.4. can allow automatic reclosing.5.
Contact Now
Byword1. can realize manual and electric energy storage.2. can realize manual and electric breaking and closing.3. can realize slow breaking and closing function.4. can allow automatic reclosing.5.
Contact Now
Byword1. can realize manual and electric energy storage.2. can realize manual and electric breaking and closing .3. can realize slow breaking and closing function .4. can allow automatic reclosing. 5.
Contact Now
Abstract1. Model and Name: Circuit Breaker Spring Mechanism CT1702. Main application and performanceThis mechanism can operate 126kV high voltage SF6 circuit breaker and gas insulated switchgear (GIS). Its performance meets the requirements of GB1984 "AC High Voltage Circuit Breakers", IEC56 "High Voltage AC Circuit Breakers" and "Product Technical Conditions".The mechanism can be electric energy storage and manual energy storage. Switch operation is divided into remote control operation, near electric operation and manual operation.3.
Contact Now
Product DescriptionOutdoor high-voltage switchgear with three-phase AC 50Hz.Composed of actuator, conductive circuit, insulation system, sealing and shell, the overall structure is three-phase common box type.It is used for dividing and closing load current, overload current, short-circuit current and other similar places.Product Technical ParametersRated voltage: 12KVRated current: 630AFrequency withstand voltage (1min): (pole to pole, pole to ground) 42KV / (vacuum break) 48KVLightning impact withstand voltage (peak): (pole to pole, pole to ground) 75KV / (vacuum interrupter) 85KVRated short
Contact Now
Byword1. Can realize manual and electric energy storage.2. Can realize manual and electric breaking and closing.3. Can realize slow breaking and closing function.4. Can allow automatic reclosing.5.
Contact Now